
12V Starter Solenoid Switch VSR0563 for Chevrolet
Applicable models:Chevrolet
Reference part number:10475654、1114587、26245186,112615、93740801、66-132,10520731,VSR0563,0685136SX,SSD8217FX,SSD8217ZD,AMDEL339,AMDEL341,10476117,93740992,138217,231929,SSD8217KG, SSD1929KG,66134,ASINEL2339 ,ASINEL2341,TT76465,SSD8217GC,SSD8217NY,SSD8217RN,FO42010041,10475646,10475654,1114587,10482844,ST1110005,93740838,1016401,10518612,SSD7034BA,SSD7034RN,1114593 1114599,1114609,10520731,SSD7217HE,PXPECB005,SSD7034ZD,6612038,93740837,PSS016 907246,SSD1929FX,BRSR11,SSD8217BA SSD7034LC.
| Rated output : | 12v |
| Pulley : | |
| Size : | |
| Weight : | Net weight:0.6KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | Starter solenoid switch |
| Specification : | 12v |
| Pulley : | |
| Brand : | nuojin |
| Number : | 93740999 |
| Quality : | NEW |
| Delivery time : | 10DAY-30DAY |





About the VSR0563 Starter Solenoid Switch
A starter solenoid is a heavy-current relay built into the starter's nose. On the VSR0563 unit, the coils, plunger and contact disc are assembled in one housing that bolts to the starter and carries the battery cable, the motor cable and the small control wire.
Heat and current are the two enemies of a solenoid. The coil sits next to the exhaust side of the engine on many installations, and the contacts carry the full starter current, so both the winding and the disc face degrade faster than the rest of the starting system.
Specification Summary
- 12V nominal coil and contact rating
- Pull-in and hold-in coil in one sealed housing
- Copper contact disc with plated terminal studs
- Direct replacement for the original mounting pattern
Reference Numbers and Cross References
These references are used for this solenoid switch in catalogues and workshop parts books:
- 1114593
- 1114599
- 10475646
- 93740999
- 10475654
- 1114587
- 26245186
- 112615
- 93740801
- 66-132
- VSR0563
- 0685136SX
- SSD8217FX
- SSD8217ZD
- AMDEL339
- AMDEL341
Application Notes
On Chevrolet installations the solenoid is reached from below or through the wheel arch. Confirm the terminal arrangement (battery stud, motor stud, control terminal) matches the old unit before bolting the new one in place.
Because solenoids are shared across starter families, one switch often covers a long list of vehicles. That breadth is useful for stock, but it makes number checking more important, not less.
How Solenoid Switches Fail
The first failure is usually electrical rather than mechanical: the copper disc erodes until it no longer makes clean contact on both studs.
Coil failure is the second. Heat soak, vibration and water ingress break down the winding insulation, so the plunger no longer pulls in and the starter never engages.
Fault Symptoms
- Click and no crank, sometimes cured by tapping the solenoid
- Intermittent starting that gets worse in cold or damp weather
- Slow cranking that improves when the solenoid is bridged
- Burning smell or discoloured terminal studs
- Battery that drains when the vehicle is parked
Testing Before Replacement
A voltage drop test across the main studs is the quickest check. More than about half a volt while cranking points to burned contacts, and the switch should be replaced rather than cleaned.
Check the earth strap and the battery terminals first. A solenoid is often replaced for a fault that lives in a corroded cable, and the new part fails the same way within weeks.
Installation Notes
Disconnect the battery before touching the main studs. Note the position of the battery cable, the motor cable and the control wire, then remove the old switch and clean the mating face. Fit the new unit with the terminals in the same order, tighten the main nuts firmly and refit the control terminal last.
After fitting, crank the engine once with the coil lead disconnected to confirm the motor circuit, then reconnect and start normally. Check for a hot terminal or a smell of burning after the first few starts.
Quality Control and Supply
Hejian Nuojin Auto Parts Co., Ltd. assembles these switches with copper contact discs, plated studs and sealed coil housings, and checks each batch for pull-in voltage, hold-in current, contact resistance and insulation. Units are packed in neutral kraft paper cartons and covered by a one-year warranty.
Frequently Asked Questions
Can I replace only the solenoid and keep the starter?
Yes. If the motor and drive still work, a new solenoid restores the circuit at a fraction of the cost of a complete starter. Check the brushes and the drive while the starter is off the vehicle.
How do I know the coil voltage is right?
The voltage is stamped on the housing or listed with the part number. A 24V switch on a 12V system will not pull in, and a 12V switch on a 24V system will burn out the winding.
Why does the starter click but not turn?
A click means the coil is working and the plunger is moving. If the motor does not turn, the main contacts are burned, the motor cable is loose or the starter motor itself has failed.
Should I replace the solenoid when I rebuild the starter?
It is the usual practice. The contacts have the same service life as the brushes, and a rebuilt starter with a worn solenoid comes back with the same complaint.
Disconnect the negative battery cable to avoid short - circuits or electric shocks during the installation process.
Prepare suitable tools, such as a 12mm box - end wrench and a 10mm wrench.
Align the push - rod of the movable iron core of the solenoid switch with the upper end of the shift fork of the starter drive end - cover.
Then install the solenoid switch onto the starter housing and tighten the fixing nuts. Generally, the solenoid switch assembly has two or three fixing nuts, which are tightened with a 10mm wrench. Pay attention to the appropriate tightening torque of the nuts to avoid over - tightening or under - tightening.
According to the markings on the terminals of the solenoid switch, connect the wires of the motor to the corresponding terminals. Usually, there are terminals such as B (or 30), M (or C), and S (or 50) on the solenoid switch. Ensure that the wires are firmly connected and the terminal nuts are tightened.
Connect the wire of the starter relay to the S (or 50) starter terminal of the solenoid switch and tighten the terminal nut.
After installation, check whether the solenoid switch is firmly fixed and whether the wires are correctly and firmly connected.
Then reconnect the negative battery cable and test the starter. Try to start the vehicle and observe whether the starter works normally, and whether the movable iron core of the solenoid switch can push the shift fork normally to make the drive gear mesh with the flywheel ring gear.
Precautions for the 12V Chevrolet Starter Solenoid Switch
Installation Precautions
- Terminal TorqueThe tightening torque for the solenoid switch terminal nuts is usually 14.7 to 17.7 N·m. Insufficient torque may cause loose wiring harnesses, circuit heating, and voltage drops, affecting starting performance. Excessive torque may damage the terminals.
- Bolt Length and WashersPay attention to the length of the fixing bolts when installing the solenoid switch. Avoid using overly long bolts that could pierce the coil bobbin and cause grounding. It is recommended to use spring washers when tightening the bolts.
- Wire ConnectionsClamp the wires of terminals B and M with two flat washers to reduce poor contact. The two fixing bolts of the solenoid switch insulation cover are prone to loosening and should be tightened during each starter maintenance.
- Lubrication of the Movable Iron CoreApply a thin layer of engine oil to the surface of the movable iron core to reduce operating resistance. Use antifreeze oil in winter.
- Installation Position and CenteringEnsure good positioning contact between the starter mounting surface, flange spigot, and the engine block or transmission mounting surface—no oil stains or rust allowed. When installing the fixing screws, tighten them alternately to avoid installation center deviation.
Usage Precautions
- Starting OperationRelease the key promptly after starting the engine to prevent the solenoid switch from working for an extended period, which shortens its service life. The normal operating time of the starter is 1.5 to 2 seconds per start, with a maximum of 5 seconds. If the engine fails to start within 5 seconds, interrupt the start and try again after a 20 to 30-second interval. If it still fails to start after 3 attempts, inspect the circuit or engine for faults.
- Power Supply VoltageEnsure the battery voltage is sufficient before starting—generally, it should be above 12V (not less than 12.14V). If the voltage is lower than this value, charge the battery to the normal voltage first to avoid damaging the battery and starter.
- Circuit InspectionRegularly check the circuit connection points and plugs of the solenoid switch. Timely address rust, corrosion, or looseness to prevent circuit heating and voltage drops that affect the starter’s normal operation.
- Avoid MisoperationDo not leave the key in the "ON" position when the engine is not in use for a long time. Before turning the ignition key to the "START" position, ensure the gearshift lever is in neutral. Do not press the accelerator pedal during ignition and starting.
References:
Professional Automotive Repair Websites
The article How to Maintain and Service Automotive Starters on Zhipai Wang mentions precautions such as the tightening torque of the solenoid switch terminal nuts (14.7 to 17.7 N·m) and the normal operating time of the starter.
Content like Disassembly and Assembly Steps of Automotive Starters on Pacific Auto Network also covers relevant precautions for starter installation and solenoid switches.
Multiple articles on Autohome, such as DIY Replacement of Starter Solenoid Switch_Buick GL6 Forum - Autohome Forum and How to Maintain Automotive Starters, explain the installation and usage precautions for starter solenoid switches.

