Applicable models:Daf, Man, Renault Trucks
Reference part number:1357593 0120468053 0120468107 0120468113 0120468053.0120468107.0120468113.0120468138. 0120468115.0120468118.0120468137.0986037770. 1986A00182,6033GB3006,6033GB3014.6033GB3054, DRA7770.DRA7770N 01178511 8033366 ,B120500755 091295,1178511,1298995,1357593, 1516402R,1528596 19025100.19025107.19025112 1800111446 1516402, 1516402,
| Rated output : | 24V 80A |
| Pulley : | 2PK 8PK 9PK |
| Size : | 24*18*17single unit inner box |
| Weight : | Net weight 6.55kg |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | Altemator |
| Specification : | 24V 80A |
| Pulley : | 2PK 8PK 9PK |
| Brand : | nuojin |
| Number : | 1298995 |
| Quality : | Remanufacture |
| Delivery time : | 10 day |





Model and Specifications: Confirm the generator model, power output, pulley specifications, and terminal definitions (typically B+, D+, W, E/N). Prefer original equipment manufacturer (OEM) parts or equivalent replacements.
Power Disconnection: Turn off the engine, apply the parking brake, and chock the wheels. First, disconnect the negative (-) battery terminal, then the positive (+) terminal (or the main power cutoff switch). Wear insulated gloves. Clean the work area of oil, dirt, and flammable materials.
Tools and Consumables: Socket set / ratchet / torque wrench, belt tensioner, multimeter (DC voltage setting), copper brush / sandpaper, anti-seize conductive grease, heat shrink tubing / electrical tape, cable ties.
Loosen the belt tensioner and remove the belt, taking a photo to record its routing.
Remove the generator mounting bolts / brackets by loosening them diagonally in sequence.
Disconnect the electrical connectors and the main B+ cable (label all terminals clearly). Remove the old generator.
Inspect the condition of the belt, idler pulleys, and tensioner for wear and cracks. Replace if necessary.
Clean the mounting surface, brackets, and bolt holes of any rust, oil, and debris. Check the condition of the locating pins / dowels.
Apply bearing grease to the new generator (as per manufacturer instructions) and ensure the pulley rotates smoothly without binding.
Position the new generator in place and thread the mounting bolts by hand until snug.
Tighten the mounting bolts diagonally in sequence to the torque specified in the vehicle manual (typically 20–30 N·m; always refer to the manual for exact values).
Install the belt and tension it using the tensioner to the specified deflection (or according to markings).
Terminal Wiring (Typical 24V Definitions):
B+: Connect to the main positive battery cable (with an integrated fuse / circuit breaker). Tighten the terminal bolt to the specified torque (typically 12–18 N·m). Apply anti-seize conductive grease to prevent corrosion.
D+: Connect to the charge indicator light / regulator field circuit, or the corresponding pin on the ECU. Ensure the connector is securely locked.
W: Connect to the tachometer signal / auxiliary output, as required for your monitoring system.
E/N: Connect to the generator housing / ground. Ensure a reliable connection to the engine block or chassis ground point. Remove any paint or corrosion from the connection points to ensure good electrical contact.
Route and secure all wiring neatly, away from hot components and moving parts, using cable ties.
Reconnect the positive (+) battery terminal first, then the negative (-) terminal. Clear any stored fault codes (if applicable).
Start the engine and operate it at idle → 2000 rpm. Observe that the charge indicator light goes out.
Use a multimeter to measure the voltage at the B+ terminal relative to ground: it should be 26.0–28.0 V (normal range for a 24V system) and remain stable under load without significant fluctuation.
Inspect the belt for proper tracking and abnormal noises. Check all wiring connections for signs of overheating or burning odor.
Strict Sequence: Before any operation, first disconnect the negative (-) battery terminal, then the positive (+) terminal. This prevents accidental short circuits, sparks, or damage to electronic components caused by tools or metal parts touching the battery terminals during disassembly and wiring.
Master Power Management: If the vehicle is equipped with a main power switch or fuse box, turn it off or disconnect the corresponding power source before performing any electrical work.
Insulated Tools: Ensure all tools (e.g., wrenches, screwdrivers) have well-insulated handles to prevent short circuits caused by hand slippage or accidental contact between the tool and other metal components.
Terminal Protection: When terminals (e.g., B+, D+) are not connected, wrap them with electrical tape or terminal protection caps to prevent dust, moisture ingress, or accidental short circuits.
Harness Inspection: Check the new generator harness for damage, aging, or exposed copper wires. Replace immediately if any defects are found.
Clean Installation Surface: Before installing the generator, thoroughly clean the mounting surface on the engine block or chassis to remove oil, rust, and debris. This is crucial for ensuring accurate positioning and secure installation.
Belt Installation: When installing the belt, ensure the pulleys are aligned to avoid belt misalignment. Use the belt tensioner with moderate force: too loose will cause belt slippage, while too tight will increase bearing load and shorten generator life.
Avoid Impact: Do not use tools like hammers to directly strike the generator housing or pulleys during installation or removal, as this may damage internal bearings or windings.
Torque Specifications: The tightening torque for generator mounting bolts and terminal bolts must strictly comply with the values specified in the vehicle service manual or generator documentation. Insufficient torque can lead to loose connections, poor contact, overheating, or even arcing. Excessive torque may damage bolts or the housing.
Reliable Grounding: The generator ground (E/N) must connect to a reliable ground point on the engine block or chassis. Poor grounding can result in insufficient charging current, unstable voltage, or even generator burnout.
Harness Routing: After installation, route and secure all wiring neatly away from hot components (e.g., exhaust pipes), moving parts (e.g., belts), and sharp edges using cable ties to prevent abrasion or entanglement.
CAN Bus Adaptation (Critical for Renault Models): For Renault trucks equipped with a CAN bus system, after generator replacement, parameter matching and coding must be performed using manufacturer-specific diagnostic equipment (e.g., Renault Diagnostic System). Otherwise, the generator may not function correctly or be flagged as faulty by the ECU.
Static Before Dynamic: Before starting the engine, use a multimeter to check for short circuits at the generator output terminals (resistance between B+ and ground should be infinite).
Correct Reconnection Sequence: When reconnecting power, first connect the positive (+) battery terminal, then the negative (-) terminal. Incorrect sequence can cause voltage surges that damage electronic equipment.
Load Testing: After starting the engine, test the generator output voltage at different speeds (idle, medium, high). With load applied (e.g., turning on headlights, air conditioning), the voltage should stabilize between 26.0–28.0V (for a 24V system) with minimal fluctuation.
Monitor for Abnormalities: During testing, closely observe the generator and wiring for unusual noises, odors, overheating, or smoke. Stop the engine immediately and inspect if any abnormalities are detected.
References:
Nature of Content: This is a customized, actionable guide and risk assessment, which I compiled based on the general installation procedure for 24V belt-driven generators in heavy-duty trucks. It integrates the specific characteristics of DAF, MAN, and Renault trucks (such as terminal definitions, CAN bus adaptation, torque ranges, etc.) with industry safety and testing standards.
Reference Basis: The core procedure (Disconnect Power → Remove Old → Clean & Position → Install New → Connect Wiring → Tension Belt → Reconnect Power & Test), terminal definitions (B+/D+/W/E/N), 24V system voltage range (26.0–28.0 V), and torque ranges are all consistent with the general specifications for commercial vehicle generator installation and the technical requirements of mainstream brands (such as Bosch / Varta). The model-specific points are based on the common configurations and maintenance experience of heavy-duty trucks from these brands.
No Public Source: These two sections do not have a unique "original link" or "publication number" and are not attributed to any cited source. They are exclusive responses generated specifically for your needs.