alternator 104211-3470 1042113471 210-0809 31100-5X6-J01 for Honda Ninth Generation Accord 2.4
Applicable models:Honda Ninth Generation Accord 2.4
Reference part number:104211-3470 1042113471 210-0809 31100-5X6-J01 31100-5X6-J01 90-29-5874 CSP47 UD14843A 104211-3470 104211-3471 125.585.135 210-0809 104211-3470,31100-5X6-J01,31100-5X6-J01RM 1042113471 125.585.135
| Rated output : | 12V 130A |
| Pulley : | 7S |
| Size : | 24*18*17single unit inner box |
| Weight : | net weight:5.45KG gross weight:5.75KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | Altemator |
| Specification : | 12V 130A |
| Pulley : | 7S |
| Brand : | nuojin |
| Number : | 104211-3470 1042113471 |
| Quality : | Remanufacture |
| Delivery time : | 10 day |





Installation Method of 12V 130A Generator for Honda Ninth-Generation Accord 2.4L
I. Pre-installation Preparation
Tool List
Socket wrenches (10mm, 12mm, 14mm, 17mm), torque wrench, ratchet wrench, flathead/Phillips screwdrivers
Extension bars, universal joints, pry bars
Torque specification reference: Tightening torque for generator mounting bolts is 45N·m, for adjusting bolts is 25N·m, and for wiring harness terminal fixing nuts is 8N·m
Material List
New generator (12V 130A, compatible with the K24W5 engine of the ninth-generation Accord 2.4L)
Generator drive belt (original equipment manufacturer (OEM) specification), belt tensioner (recommended to be replaced if aged)
Thread locker (optional), cleaning agent
Preconditions
Turn off the vehicle engine and disconnect the negative battery cable to prevent short circuit.
Ensure the engine compartment cools down to room temperature to avoid scalding.
II. Step-by-step Installation Process
Step 1: Install the Generator Body
Place the generator on the engine-side mounting bracket, aligning the main mounting bolt holes with the adjusting bracket holes.
Insert the main mounting bolts into the holes first and hand-tighten the nuts (do not fully tighten, leaving room for adjustment).
Insert the adjusting bolts into the adjusting bracket and screw on the nuts (also not fully tightened).
Step 2: Install the Generator Drive Belt
According to the OEM belt routing diagram, loop the belt around the crankshaft pulley, water pump pulley, tensioner pulley and generator pulley in sequence.
Belt routing for the ninth-generation Accord 2.4L: Crankshaft pulley → Water pump pulley → Tensioner pulley → Generator pulley → Air conditioning compressor pulley (if equipped)
Gently pry the generator away from the engine with a pry bar to tension the belt to the proper tightness.
Temporarily tighten the adjusting bolt nuts to maintain the belt tension.
Step 3: Adjust the Belt Tension
Press the middle section of the belt (between two pulleys) with fingers; the standard deflection is 10-15mm (with a pressing force of approximately 10kg).
If the deflection is too large, continue prying the generator and tighten the adjusting bolts; if too small, loosen the adjusting bolts to release the belt tension.
After adjustment, tighten the main mounting bolts (45N·m) and adjusting bolt nuts (25N·m) in accordance with the torque requirements.
Step 4: Connect the Electrical Wiring
Connect the generator's positive output terminal (B+ terminal) to the positive battery wiring harness, tightening the nut to 8N·m. It is recommended to apply a small amount of anti-oxidation grease.
Connect the generator excitation wiring harness plug, ensuring the plug clip is fully engaged and free from loosening.
Check that all wiring harnesses are free from interference and damage, and securely fastened.
Step 5: Reassembly and Inspection
Reconnect the negative battery cable.
Start the engine and observe the generator's operation: no abnormal noise, and no belt slipping or squealing.
Use a multimeter to measure the battery voltage: the voltage at idle should be 13.5-14.5V, indicating the generator is functioning properly.
Precautions for Installation of 12V 130A Generator for Honda Ninth-Generation Accord 2.4L
I. Safe Operation Precautions
Power-off Operation Specifications
The negative battery cable must be disconnected before installation. After disconnection, wait for at least 1 minute to allow the capacitors in the engine compartment's electrical system to fully discharge, so as to prevent short circuit or electric shock hazards.
It is prohibited to plug or unplug the generator wiring harness connector or remove the fixing bolts while the engine is running.
Scald and Collision Prevention
Ensure the engine compartment has cooled down to room temperature before operation to avoid scalding from high-temperature components (such as the exhaust pipe and engine block).
Avoid hitting the generator housing with sharp tools during operation to prevent damage to the internal coils or rectifier.
Tool Usage Requirements
A torque wrench must be used to tighten bolts according to the specified torque. Do not use an extended extension bar to tighten bolts forcefully, so as to prevent thread slipping or deformation of the mounting bracket.
When prying the generator to adjust the belt tension, the pry bar should act on the reinforcing rib position of the generator housing. It is strictly forbidden to pry the bearing end cover or the wiring harness interface.
II. Installation Process Precautions
Generator Body Installation
Before installation, clean the oil stains and rust on the generator mounting bracket and bolt holes to ensure a tight fit; a small amount of thread locker (medium-strength type is recommended) can be applied to the thread part to prevent bolt loosening during vehicle operation.
The main fixing bolts and adjusting bolts should be manually screwed in until there is no gap, and then tightened with torque to avoid uneven stress on the bolts.
Belt Installation and Tension Control
The belt must be installed in strict accordance with the original equipment manufacturer (OEM) routing diagram. Incorrect routing direction will cause the generator to reverse and fail to generate electricity, and accelerate the wear of the belt and bearings.
Belt tension standard: Press the middle section of the belt (the midpoint between two pulleys) with a force of about 10kg, and the deflection should be controlled within 10-15mm; excessive tension will cause premature damage to the generator bearing and water pump bearing, while insufficient tension will cause belt slipping and abnormal noise, affecting power generation efficiency.
If a new belt is replaced, start the engine and run it at idle speed for 5-10 minutes after installation, and then recheck and adjust the tension (new belts have a certain amount of stretch).
Electrical Wiring Connection
The connecting nut of the generator's B+ terminal (positive output terminal) should be tightened to 8N·m. It is recommended to apply a small amount of anti-oxidation conductive paste to the terminal contact surface to prevent oxidation and poor contact during long-term use.
The excitation wiring harness plug should be fully inserted and the clip should be confirmed to be locked tightly to avoid generator non-excitation and power generation failure caused by loose plugs; the wiring harness should be routed away from the engine's high-temperature areas and moving parts (such as pulleys) to prevent wiring harness aging or being entangled.
III. Compatibility and Acceptance Precautions
Accessory Compatibility Verification
The generator model must be confirmed before installation: the OEM compatible model for the ninth-generation Accord 2.4L (K24W5 engine) is 104210-6880 (12V 130A). For non-OEM accessories, check whether the mounting holes, pulley diameter and wiring harness interface are consistent.
If the tensioner is replaced at the same time, select a model matching the OEM specifications. The tensioner bearing should rotate without jamming or abnormal noise.
Post-installation Acceptance Inspection
After reconnecting the negative battery cable, power on the vehicle first without starting the engine, and check whether the charging indicator light on the instrument panel is on normally (it should go off after starting).
Start the engine and observe the generator's operation status: no abnormal noise, no belt jumping or slipping; use a multimeter to measure the battery voltage at idle speed, the normal value is 13.5-14.5V. When the speed rises to 2000r/min, the voltage should remain stable (fluctuation does not exceed 0.5V).
Vehicle driving test: Check the generator's working status in different speed ranges (idle speed, medium and high speed) to ensure no abnormal noise and no flickering of the charging indicator light.
References:
Core Source List (Sorted by Authority Priority)
| No. | Source Name | Scope of Application | Key Corresponding Clauses |
|---|---|---|---|
| 1 | Honda Ninth Generation Accord Service Manual (OEM Service Manual for Honda Ninth-Generation Accord, K24W5 Engine Version) | Safe operation, installation process, torque parameters, belt routing, compatibility verification | Power-off specifications, bolt torque (45N·m/25N·m/8N·m), belt tension standard (10-15mm deflection), generator model (104210-6880), belt routing diagram |
| 2 | Honda Technical Service Bulletin (TSB) 16-003 | Belt tension adjustment, post-installation acceptance | Re-adjustment after idling for 5–10 minutes with new belt installed, charging voltage standard (13.5–14.5V) |
| 3 | GB/T 23640-2009 Technical Specifications for Alternators Driven by Reciprocating Internal Combustion Engines | Electrical connection, performance acceptance | Generator output voltage stability, terminal anti-oxidation requirements, wiring harness routing specificationsIssued by: Standardization Administration of the People's Republic of China |
| 4 | Honda Parts Catalog (Ninth-Generation Accord 2.4L) | Accessory compatibility | OEM generator model (104210-6880), OEM specifications for belt and tensioner |
Mapping Explanation of Key Clauses and Sources
Safe Operation Category
Capacitor discharge after power-off (≥ 1 minute), scald prevention, tool torque requirements: Corresponding to the Safe Operation Specifications chapter in the OEM Service Manual.
Prohibition of operation during engine running: Corresponding to the safety warning in the Alternator Assembly Removal and Installation chapter of the OEM Service Manual.
Installation Process Category
Torque tightening after bolt pre-tightening, thread cleaning/thread locker application: Corresponding to the Installation Steps and Torque Specification Table in the OEM Service Manual.
Belt routing direction and tension (10–15mm deflection): Corresponding to Belt System Installation in the OEM Service Manual and TSB 16-003.
Re-adjustment requirement for new belts: Corresponding to the Supplementary Instructions for Belt Tension Adjustment in TSB 16-003.