Factory sales 12v 40A Agricultural machinery equipment alternator for AEBI TC07 113921 CAL40314AS 133745A1 1002114611, DAN2020 Factory Sales
Applicable models:KUBOTA D1105 D722 D902 D1305
Consult now
Reference part number:1002114611 DAN2020 100211-4520 16241-64010 D1005 D1105 D722 D905 D1305 100211-1670 16231-24011 16241-64010 16241-64011 133745A1 100211-1670 436497 1624164013、6643664013、6643664014 1002114520 1623164010 1623164011 12190 1623164011、1623164013、1624164012 1624164013 16241-64013 16241-6401-3 16241-64015 16241-64013 16241-64012 16241-64014
Product Attributes
| Rated output : | 12V 45A |
| Pulley : | 1PK |
| Size : | 24*18*17single unit inner box |
| Weight : | net weight:3.25KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
Product Details
| Type : | ACgenerator Alternator |
| Specification : | 12V 45A |
| Pulley : | 1PK |
| Brand : | NUOJIN |
| Number : | 133745A1 |
| Quality : | REMANUFACTURE |
| Delivery time : | 10DAY |





Kubota 12V generators are mostly used in its tractors, excavators and other equipment. The core installation process is similar to that of general engine generators, but it needs to adapt to the power connection characteristics of agricultural machinery. The detailed installation method is as follows. It is recommended to refer to the corresponding equipment maintenance manual during operation:
Pre-installation Preparation
- Tool and accessory preparation:Prepare a 12V original or compliant generator suitable for Kubota equipment, along with socket wrenches, torque wrenches, belt tensioning tools, rags, conductive paste, and insulating gloves. If the equipment circuit needs to be powered off for a long time, an on-board memory protector can be prepared to prevent the loss of system parameters.
- Safety and preliminary inspection:First, turn off the equipment engine and let it cool down, then disconnect the negative terminal of the battery to avoid short circuits and electric shocks. Next, clean the dust and oil stains in the generator installation area of the engine compartment, and check if the mounting bracket is deformed or cracked. Repair or replace it if damaged; at the same time, verify that the interface and size of the new generator are consistent with the old one to ensure compatibility with the current Kubota model.
Removing the Old Generator (for replacement scenarios)
- Loosen the drive belt:Use a belt tensioning tool to release the belt tension. After the belt is loose, remove it from the pulley of the old generator and remember the belt routing to facilitate subsequent installation.
- Disconnect electrical connections:Locate the electrical interface of the generator, press the plug buckle to pull out the control circuit connector; then use a wrench to loosen the fixing nut of the thick output wire of the generator, disconnect the output wire and mark the positive and negative poles of the circuit to avoid confusion during subsequent wiring.
- Remove fixing bolts:Use a wrench to gradually loosen and remove the bolts fixing the old generator in a diagonal sequence. Store the bolts properly to prevent loss, and finally gently take out the old generator to avoid collision with surrounding pipelines and components.
Installing the New Generator
- Initially fix the unit:Place the new generator stably on the mounting bracket, align it with the bolt holes of the bracket, and screw in the previously removed bolts by hand for positioning. Do not tighten them temporarily to reserve space for subsequent adjustments.
- Reset the drive belt:According to the remembered routing, put the belt on the pulley of the new generator. Operate the tensioning tool to adjust the belt tension; it is appropriate for the middle of the belt to sink 1-2cm when pressed. Ensure the belt is fully embedded in the pulley groove without deviation or distortion.
- Tighten fixing bolts:After confirming that the generator is properly positioned and the belt fits well, use a torque wrench to gradually tighten the fixing bolts in a diagonal sequence. The torque is recommended to be controlled between 18-25N・m to avoid loose bolts falling off due to vibration or damaged bracket threads caused by over-tightening.
- Restore electrical connections:First, connect the thick output wire of the generator, tighten the fixing nut, and apply a small amount of conductive paste to improve contact stability; then align the control circuit connector with the interface and insert it smoothly until a click from the buckle is heard to ensure a secure connection. Do not force insertion or removal to avoid damaging the pins.
Commissioning and Inspection
- Power-on test run:Reconnect the negative terminal of the battery, start the engine of the Kubota equipment, and observe if the charging indicator light on the instrument panel goes out. If it goes out, it initially indicates that the generator is working normally; if it stays on, check the wiring or belt installation.
- Test voltage parameters:Use a multimeter to measure the voltage across the battery. The voltage should be stable at 13.5-14.5V when the equipment is idling, and also remain stable during acceleration. If the voltage is below 13V or above 15V, stop the machine to check the wiring connections or belt tension.
- Troubleshoot operation abnormalities:Observe if there is abnormal noise during the generator's operation, and check if the electrical connectors are loose or overheated; reconfirm that the belt does not slip and the mounting bracket has no vibration. The installation is completed after ensuring there are no potential faults.
The precautions for installing Kubota 12V generators must cover the entire process including pre-installation preparation, mechanical installation, electrical connection, and test run. Combined with their common application in small agricultural machinery or equipment, special focus should be placed on stability, safety, and compatibility. The details are as follows:
Pre-installation Preparation
- Equipment and accessory verification:First, confirm that the generator model is compatible with the corresponding Kubota equipment (such as specific models of agricultural machinery, small machinery). Check that the generator itself has no transportation damage and the rotor rotates smoothly without jamming. Verify that accessories such as anchor bolts, gaskets, and terminal blocks are complete and intact. For water-cooled units, additionally check that cooling system components are free of damage and leakage.
- Foundation and site preparation:The installation ground must be compacted and level, with the foundation plane deviation controlled within ±3mm. If using a concrete foundation, ensure there are no cracks or oil stains. Reserve sufficient ventilation space for indoor installation, keep away from flammable, explosive, and corrosive substances, and configure fire-fighting equipment simultaneously; for outdoor installation, avoid waterlogged and direct sunlight areas.
- Tool and protection preparation:Prepare tools such as socket wrenches, torque wrenches, levels, multimeters, and megohmmeters, as well as consumables like rags, conductive paste, and sealant. Operators must wear protective gloves and goggles to avoid scratches from oil stains or components during installation.
References:- The precautions regarding the installation of Kubota 12V generators you previously inquired about do not have a single exclusive source. They are mainly derived from the official maintenance manuals for corresponding Kubota models, supplemented by practical experience from agricultural machinery/generator maintenance platforms and general specification documents. The details are as follows:
Official Maintenance Manuals for Kubota Models
- This serves as the core basis for the installation precautions. For example, the maintenance manuals for Kubota's J series and GL series diesel generators (such as GL6000, GL11000, etc.) clearly include generator disassembly and assembly processes, wiring diagrams, bolt tightening torque standards, and voltage regulator commissioning procedures. The maintenance manual for models like J116-STD details generator structure, installation specifications for circuit emergency relays, and wiring safety precautions during maintenance. GL series manuals also explicitly stipulate installation protection for electrical components and key wiring operations—all of which correspond to core installation precautions such as circuit safety and mechanical fixation. While some manuals require paid purchase, they cover exclusive installation details for different compatible models.
Free Public Equipment Operation Manuals
- Platforms like ManualsLib host free operation and maintenance manuals for multiple Kubota 12V-related generators (e.g., J116-STD, J112-AUS). These manuals include pre-installation safety checks, wiring specifications, and basic requirements for hoisting and fixation. For instance, they mention practical points such as disconnecting the battery before installation, ensuring secure connections to avoid contact with rotating parts during wiring, and marking torque ranges for some bolts—all of which can be directly used as reference for installation operations.
Practical Sharing Platforms for Agricultural Machinery and Generator Maintenance
- Technical summaries from agricultural machinery maintenance forums and offline repair shops supplement practical installation precautions. Kubota generators are often used with agricultural machinery and small engineering equipment; repair technicians have summarized on-site tips such as "avoiding direct contact between steel wire ropes and the generator housing during hoisting" and "cleaning terminals to prevent oxidation before wiring." Though not included in official manuals, these details fill gaps in practical operations and are widely available on agricultural machinery maintenance technical exchange communities or offline training materials.
General Diesel Generator Installation Specification Documents
- General safety operating procedures for 12V diesel generator sets also provide valuable references for Kubota 12V generator installation. For example, diesel generator set installation specifications included in Originality Document Library cover grounding resistance standards, hoisting protection requirements, and pipeline connection tightening—general guidelines applicable to all 12V diesel generators. When combined with Kubota's official requirements, these specifications enhance the completeness of installation precautions.
Related Articles
Discover what vehicles use auto starter systems and how Auto Starter car technology improves safety, convenience, and performance. Learn about manufacturer production, factory supply, and modern applications for cars, trucks, and commercial vehicles.....
Looking for a complete Auto Starter guide? This article explains how auto starters work, types, symptoms, maintenance tips, and how manufacturers and factories supply high-quality starters for global production and bulk orders.....
Learn everything about starter parts, how they work, signs of failure, maintenance tips, and how a professional manufacturer with factory production ensures stable, high-quality starter components for global vehicle owners.....
Explore the real-world Auto Starter disadvantages in industrial and automotive production. Learn how auto starter systems affect reliability, cost, maintenance, and factory manufacturing efficiency.....
Discover what a starter solenoid does in a vehicle, how it works with the starter motor, signs of failure, and why quality starter solenoid production from a professional manufacturer and factory matters for reliable performance.....
Explore common Boat Starter types and learn which marine engines they fit best. As a professional Boat Starter manufacturer with factory production and bulk supply capability, we provide reliable starting solutions for outboard, inboard, and diesel marine engin....