DFM Heavy Truck Parts JFZ2720 C5267512 Alternator
Applicable models:DFM Heavy Truck Parts
Reference part number: JFZ2720 C4984043 C5267512 C4930794 C4984043
| Rated output : | 80A |
| Pulley : | 8pk |
| Size : | 27*26*21cm single unit inner box |
| Weight : | NET WEIGHT:6.65KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | Acgenerator |
| Specification : | 80A |
| Pulley : | 8PK |
| Brand : | NUOJIN |
| Number : | JFZ2720 |
| Quality : | Renovate |
| Delivery time : | 10 days |




Installation Method of 80A Generator for Dongfeng Tianjin
I. Core Installation Method (How-to)
1. Pre-installation Preparation
Model Compatibility: Confirm that the original part number of the 80A generator matches the engine nameplate, and its specifications are consistent with the power supply system.
Component Inspection: Check that the generator has no external damage, the pulley is free of deformation, the terminals are rust-free, and the bearing rotates smoothly without jamming.
Tool List: Torque wrench (50–300 N·m), socket set (including M10/M12/M14 sizes), Phillips screwdriver, belt tensioner tool, insulating gloves, safety goggles.
Safety Power-off: Disconnect the negative battery cable to prevent short circuits/electric shocks.
2. Mechanical Fixing of the Generator
Positioning: Fit the generator to the engine mounting bracket and align it with 2 mounting bolt holes (some models are equipped with an adjusting bracket).
Pre-tightening: Manually screw in the mounting bolts to ensure full thread engagement without skew.
Final Fastening: Tighten the bolts symmetrically with a torque wrench in 2 gradual steps, complying with the following torque standards:
M12 bolts: 45–55 N·m
M14 bolts: 85–95 N·m
Adjusting bracket bolts: 19.6–26.5 N·m
Refer to the Dongfeng Tianjin Maintenance Manual for the final torque value.
3. Belt Installation and Tension Adjustment
Installation: Fit the belt onto the crankshaft pulley, water pump pulley and generator pulley in sequence, and finally mount it on the tensioner pulley.
Tension Adjustment: Use a belt tensioner tool to adjust the tension to a moderate level (pressing the middle of the belt should allow a deflection of 10–15 mm, with no slipping or abnormal wear).
Inspection: Start the engine and observe that the belt runs smoothly without deviation or abnormal noise.
4. Electrical Wiring Connection
Main Power Supply (B+): Attach the terminal of the thick positive battery cable to the main terminal of the generator with a flat washer and a spring washer installed, tighten to a torque of 25–30 N·m.
Field Wire (D+): Secure the terminal of the thin wire to the field terminal, tighten to a torque of 8–10 N·m to avoid poor contact.
Wiring Inspection: Ensure cables are free of damage, do not interfere with high-temperature components, and terminals are free of loosening.
5. Reset and Test
Power Restoration: Reconnect the negative battery cable.
Cleaning and Inspection: Clean oil stains on the generator surface and check for no leakage at the joint surface seal.
Test Run: Start the engine and check that the charging voltage (13.5–14.7 V) and charging current are normal, with no abnormal noise and no belt slipping.
Cautions for Installation of 80A Generator for Dongfeng Tianjin
I. Electrical Safety Cautions
Full-process Power-off Operation
The negative battery cable must be disconnected before installation. Live-line work is strictly prohibited to prevent short-circuit sparks from causing personnel burns or burnout of the generator and electronic control unit (ECU).
Reconnecting the negative cable is strictly prohibited before the wiring connection is fully confirmed to be correct, so as to avoid the formation of a short-circuit loop caused by tools touching the terminals.
Wiring Specification Requirements
The main power cable (thick cable) must be connected to the main terminal (B+), and the field wire (thin wire) to the field terminal (D+). Reverse connection is strictly forbidden, otherwise it will directly burn out the generator rectifier or vehicle ECU.
Flat washers and spring washers shall be added to the wiring terminals, which should be tightened according to the specified torque (25–30 N·m for main terminals, 8–10 N·m for field terminals) to eliminate the hidden danger of terminal ablation caused by poor contact and overheating.
Cables must be firmly fixed with buckles to avoid contact friction with high-temperature or moving components such as exhaust pipes and cylinder blocks, preventing insulation layer damage and electric leakage.
Prohibition of Unauthorized Testing
Starting the engine without connecting the battery is strictly prohibited. The generator’s no-load high-speed operation will generate overvoltage, which may breakdown internal electronic components.
Direct short-circuiting of terminals with metal tools to test power generation status is prohibited. This practice is prone to causing short circuits and cannot accurately judge the generator’s working condition.
II. Mechanical Installation Cautions
Bolt Application Specifications
Original high-strength bolts must be used for installation; replacement with ordinary bolts is prohibited. The high-frequency vibration during engine operation is likely to cause ordinary bolts to break, leading to generator detachment accidents.
Bolts shall be tightened gradually in 2 steps following a symmetrical sequence, strictly complying with the torque standards: 45–55 N·m for M12 bolts, 85–95 N·m for M14 bolts, 19.6–26.5 N·m for adjusting bracket bolts. Over-torquing is strictly prohibited to prevent thread slipping or mounting bracket deformation.
Belt Tension Control Requirements
The belt tension shall be kept moderate. The adjustment standard is: pressing the middle part of the belt by hand should allow a deflection of 10–15 mm.
Excessively loose tension will cause belt slipping and insufficient power generation; excessively tight tension will accelerate the wear of generator bearings and water pump bearings, shortening the service life of components.
After installation, check the coaxiality of the pulleys. The radial error between the generator pulley and the crankshaft pulley shall be ≤ 0.1 mm to avoid belt deviation and abnormal wear.
Requirements for Cleaning of Joint Surfaces
The joint surface between the generator and the mounting bracket shall be thoroughly wiped with a cleaning agent to remove oil stains, iron filings and rust, ensuring tight fit without skew and preventing resonance noise during generator operation.
Check the integrity of the generator suspension rubber sleeve. If aging or cracking is found, replace it in a timely manner to improve shock absorption effect.