
Alternator 2871A705 A007027 2871A701 2871A702 714/40208 3991485 12814N 102211-8140, 102211-8150, 714-40208, 714/40208, T416234, T416349 FOR Perkins Cat Caterpillar M322C
Applicable models:Perkins Cat Caterpillar M322C
Reference part number:A007027 2871A701 2871A702 714/40208 3991485 2871A705 QWB23650251023 12814N 102211-8140, 102211-8150, 714-40208, 714/40208, T416234, T416349 225-3146, 225-3147, 346-9826, 3469825, 424-6821 063377465010, 63307466, 63377465, 63377466 MAN7465,
| Rated output : | 24V 75A 55A |
| Pulley : | |
| Size : | |
| Weight : | Net weight 5.7kg |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Presale |
| Warranty : | 1 year |
| Product number : |
| Type : | Alternator |
| Specification : | 24V 75A 55A |
| Pulley : | |
| Brand : | NUOJIN |
| Number : | 2871A705 |
| Quality : | refurbish |
| Delivery time : | 30 days |





The installation steps for the Perkins 24V generator are as follows: • Install the bracket: If necessary, install the alternator bracket onto the cylinder head. Position the bracket on the cylinder head such that the arrow and the word "UP" are in a vertical position. Install the bolts onto the bracket, tighten them by hand first, and then torque the bolts to 44N・m (32lbft). • Install the pulley: If necessary, install the alternator pulley. Mount the pulley and nut onto the alternator shaft. Use an Allen wrench to secure the alternator shaft, and a ring spanner with a handle to tighten the nut to a torque of 80N・m (59lbft).Install the generator: Mount the alternator onto the alternator bracket, install the bolts onto the alternator, then install the nuts onto the bolts, and tighten them by hand. • Install other components: Install the bracket, then install the bolts and washers onto the alternator, tighten them by hand, and then install the bolts and nuts, tightening them by hand. • Install the V-belt: Install the V-belt according to the relevant steps.Tighten bolts and nuts: Tighten the previously installed nuts and bolts to a torque of 22N・m (195lbin). Meanwhile, tighten the bolts and washers to a torque of 22N・m (195lbin) as well. Finally, tighten the nuts and bolts to a torque of 44N・m (32lbft). • Connect the wiring harness assembly: Connect the wiring harness assembly to the alternator. • Power on: Turn the battery disconnect switch to the on position.
When installing a Perkins 24V generator, in addition to following the correct installation steps, the following precautions should be noted:Installation Environment • Good Ventilation: The installation location must have air inlets and outlets of appropriate area to ensure smooth air circulation. There should be sufficient air inlets at the generator end and good air outlets at the diesel engine end, with the area of the air outlets being more than 1.5 times that of the water tank. • Clean Environment: The area around the generator should be clean. There should be no items nearby that produce corrosive gases or vapors such as acidic or alkaline substances, nor should there be obstacles that hinder air circulation. At the same time, it should be kept away from flammable and explosive items.Basic Installation • Ground Hardening: Before placing the generator base in contact with concrete, attention should be paid to the hardening of the on-site ground and the quality of the base casting to ensure that the unit can be placed stably. • Shockproof Treatment: Special shockproof pads or base bolts should be placed between the unit and the foundation to reduce vibration and noise during the operation of the generator. Grounding Requirements • Reliable Grounding: The generator shell must have a reliable protective grounding. For generators that require direct neutral grounding, the neutral grounding must be performed by professionals, and lightning protection devices must be installed. It is strictly forbidden to use the grounding device of the mains power for direct neutral grounding.Grounding Requirements • Reliable Grounding: The generator housing must have a reliable protective grounding. For generators that require direct neutral grounding, the neutral grounding must be performed by professionals, and lightning protection devices must be installed. It is strictly prohibited to use the grounding device of the mains power for direct neutral grounding. Pipeline Connection • Exhaust Pipe: When installed indoors, the exhaust pipe must be led outdoors. The diameter of the pipe must be greater than or equal to the smoke outlet diameter of the muffler. The number of elbows in the connected pipeline should not exceed 3 to ensure smooth exhaust flow. The pipe should be inclined downward by 5°-10° to prevent rainwater from entering; if conditions do not allow the exhaust pipe to be installed vertically upward, a rain cover must be added.Wire connection • Firm connection: When connecting the wire harness assembly to the alternator, ensure the connection is firm and the contact is good to avoid looseness or poor contact. At the same time, pay attention to whether the specifications of the wires meet the requirements of the generator to prevent the wires from overloading and heating up. • Correct polarity: If battery connection is involved, ensure the positive and negative poles of the battery are connected correctly to avoid damaging the generator or other electrical equipment due to reverse polarity connection.Other Notes • Follow the Instructions: Operate strictly in accordance with the installation instructions and operation manual of the Perkins generator. Do not arbitrarily change the installation steps and parameters. During the installation process, use appropriate safety equipment and tools, and follow relevant safety regulations and operating procedures. • Inspection and Acceptance: After the installation is completed, a comprehensive inspection should be carried out, including checking whether each component is installed correctly, whether the bolts are tightened, and whether the pipe connections are sealed. At the same time, a trial run of the generator should be conducted to observe whether it operates stably and whether the voltage and current output are normal.
References:The content of this passage is mainly derived from some documents and websites. Among them, contents such as "The installation site must have air inlets and outlets of appropriate area... There should also be no obstacles that hinder air circulation" and "When installing indoors, the smoke exhaust pipe must be connected to the outdoors... to prevent rainwater from entering" are from the document "What Should Be Paid Attention to During the Installation of Perkins Diesel Generators" on the Originality Document platform. The content "The generator shell must have a reliable protective grounding... It is strictly forbidden to use the grounding device of the commercial power for direct neutral grounding" also comes from this document. The content "Strictly follow the installation instructions and operation manual of the Perkins generator for operation... and abide by relevant safety regulations and operating procedures" is consistent with the content in the document "Generator Installation Technology".

