Alternator 11270、8L8Z-10346-A、8L8Z-10346-C、8L8T-10300-AA forFord
Applicable models:Ford
Reference part number: 11270、8L8Z-10346-A、8L8Z-10346-C、8L8T-10300-AA 11270N,ZZC6-18-300、ZZC8-18-300 8L8T10300AA,8L8TAA,8L8Z10346A 8L8Z10346C,8L8Z10V346CRM,ALM4296BS AJ1118300B、AJTM18300B ,ZZC618300 A3TJ2291、A3TJ2291ZC
| Rated output : | 12V 150A |
| Pulley : | 6PK |
| Size : | 24*18*17single unit inner box |
| Weight : | Net weight: 6.15kg Gross weight: 6.55kg |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | ACgenerator Alternator |
| Specification : | 12V 150A |
| Pulley : | 6PK |
| Brand : | NUOJIN |
| Number : | 8L8Z-10346-A、8L8Z-10346-C |
| Quality : | Remanufacture |
| Delivery time : | 30DAY |






The installation method of the Ford 12V generator varies depending on the model. The following takes the Ford Focus as an example to introduce its installation method: • Install the air duct on the generator: If the air duct on the generator has been removed before, it needs to be installed first, then tighten the fixing bolts to a torque of 12 N·m (106 lb·in). • Install the generator: Install the generator in the designated position, screw on the generator fixing bolts, and temporarily tighten them by hand without reaching the specified torque. • Install the generator studs: Install 2 generator studs and tighten them to 24 N·m (18 lb·ft).Install generator nuts: Install 2 generator nuts and tighten them to 47 N·m (35 lb·ft). • Tighten generator fixing bolts: Tighten the previously hand-tightened generator fixing bolts to a torque of 47 N·m (35 lb·ft). • Connect generator B + terminal: Install the generator B + terminal onto the generator, screw on the nut, tighten it to a torque of 17 N·m (150 lb·in), and then install the protective cover onto the nut. • Install generator lower air duct: Install the generator lower air duct in the corresponding position.Install the accessory drive belt: Rotate the front-end accessory drive (FEAD) belt tensioner clockwise, then install the FEAD belt. • Install the accessory drive splash shield: Place the accessory drive splash shield in the correct position, install 2 screws, and tighten the screws to 5 N·m (44 lb·in). • Install the center support bracket: Install the center support bracket and 3 bolts, and tighten the bolts to 30 N·m (22 lb·ft).Install the right half - shaft: Install the right half - shaft in accordance with the relevant steps in the vehicle maintenance manual. • Connect the generator electrical connector: Correctly connect the electrical connector of the generator to the generator. • Connect the battery: Finally, reconnect the vehicle battery to complete the installation of the generator.
When installing a Ford 12V generator, the following precautions should be noted: • Safe Operation: Before operation, make sure the vehicle is parked stably and turned off, and disconnect the negative battery terminal to prevent dangers such as short circuits and electric shocks. • Accessory Selection: Prioritize choosing Ford original or authorized generators to ensure their reliable quality and compatibility with the vehicle. Avoid using mismatched accessories, which may cause installation problems or affect generator performance. • Component Cleaning: During installation, ensure that the generator's connectors and surfaces are clean, free of oil, dust, or impurities to guarantee good electrical connections and avoid malfunctions caused by poor contact.Installation Specifications: Install strictly in accordance with the steps in the Ford vehicle repair manual, use appropriate tools such as a torque wrench, tighten bolts or nuts according to the specified torque value to ensure the generator is firmly installed. • Belt Adjustment: When installing the belt, ensure that the belt is in good condition with no wear or damage. When adjusting the belt tension, it should have an appropriate tightness. Generally, this can be judged by pressing the middle of the belt and checking its deflection. Usually, a belt deflection of about 1/4 inch is appropriate. If it is too loose, it will cause the belt to slip, affecting power generation efficiency; if it is too tight, it will increase the load on the belt and generator bearings.Circuit Connection: When connecting electrical circuits, they must be connected accurately according to the original connection method. Ensure that wire plugs and cables are firmly and correctly connected to avoid reverse connection or loosening. At the same time, care should be taken to prevent the circuits from rubbing against or interfering with other components. • Test and Inspection: After installation, reconnect the negative pole of the battery, start the vehicle, and check if the generator is working normally. Observe whether the charging indicator light on the instrument panel goes off and whether the reading of the voltmeter or charging system is within the normal range. If there is any abnormality, stop the machine in time for inspection and troubleshooting.
References:The "passage" you are referring to is about the installation precautions for Ford 12V generators, and its content is mainly sourced from professional automotive repair websites, automotive repair manuals, etc. Among them, contents such as "Before operation, be sure to park the vehicle stably, turn off the engine, and disconnect the negative pole of the battery to prevent dangerous situations such as short circuits and electric shocks", "Prioritize choosing Ford original or authorized generators", "During installation, ensure that the generator's connectors and surfaces are clean", "Strictly follow the steps in the Ford vehicle repair manual for installation, use appropriate tools such as a torque wrench, and tighten bolts or nuts according to the specified torque value" are all mentioned in articles related to Ford generator matching tutorials and precautions on the Qichedashi website. For example, the articles with web links https://m.qcds.com/article-obd/gmJ7j and https://m.qcds.com/articleContent such as "Check whether the generator is working properly. Observe whether the charging indicator light on the dashboard is off and whether the reading of the voltmeter or charging system is within the normal range" is consistent with the precautions in the Ford generator installation guide on the First Construction Machinery Network.